Print this page Email this page Users Online: 299
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2015  |  Volume : 9  |  Issue : 1  |  Page : 38-43

Comparing the impact of using erbium yttrium aluminum Garnett laser or conventional scalpels and burs for the surgical removal of partially erupted mandibular third molars on pain, swelling, trismus, and anxiety


Department of Oral and Maxillofacial Surgery, Institute of Health Sciences, Marmara University, Istanbul, Turkey

Correspondence Address:
Erol Kucukkeles
Kardelen Evleri E Blok K: 4 D: 9, Levazim Mahallesi Muhtarligi, Birlik Sokak, Istanbul
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0976-2868.157598

Rights and Permissions

Aim: Standard method of extraction of partially impacted lower third molars is with a scalpel, and a drill. The aim of this study is to use Er:YAG laser for partially impacted lower third molar removal, and compare anxiety, pain, swelling, and trismus observed after the procedure, with the standard method. Materials and Method: The study was performed on 40 patients who applied to our clinic for the extraction of their partially impacted lower third molars. None of the patients included in the study had any systemic illnesses, and had an age range of 18-40. The patients were divided into 2 groups of 20, and the first group had their procedures done with the Er:YAG laser whereas the second group had their procedures done with scalpels and burs. All the patients filled out the STAI survey preoperatively. In addition, measurements of distances between reference points on the face, and maximum mouth opening were recorded from all patients preoperatively. The patients filled out visual analogue scales every 2 hours for the first 12 hours and then at the 24th hour. All the measurements were repeated when the patients came for suture removal, and then these values were compared with the preoperative values. Results: Laser group had less swelling and trismus compared with the control group, and the difference was statistically significant. Pain values of the laser group were lower when compared with the control group, the difference was not statistically significant. There was no statistical difference of the anxiety levels.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3614    
    Printed230    
    Emailed0    
    PDF Downloaded323    
    Comments [Add]    

Recommend this journal